Activated carbon filter

Key words:Water Filter、UV Sterilizer、Ion Exchange Water softener

In the pretreatment system, the activated water-based carbon filter can absorb the residual chlorine that cannot be removed in the pre-filtration to prevent the reverse osmosis membrane from being oxidized and degraded by it. It has obvious adsorption and removal effect on water odor, colloid and pigment, heavy metal ions, etc., and also has the effect of reducing COD. The SDI value of RO influent can be further reduced to ensure SDI<5 and TOC<2.0ppm.
Inquiry

Activated carbon filter

In the pretreatment system, the activated water-based carbon filter can absorb the residual chlorine that cannot be removed in the pre-filtration to prevent the reverse osmosis membrane from being oxidized and degraded by it. It has obvious adsorption and removal effect on water odor, colloid and pigment, heavy metal ions, etc., and also has the effect of reducing COD. The SDI value of RO influent can be further reduced to ensure SDI<5 and TOC<2.0ppm.

product description

The work of an activated carbon filter is done through a carbon bed. The activated carbon particles that make up the carbon bed have many micropores and huge specific surface area, and have strong physical adsorption capacity. The water passes through the carbon bed, and the organic pollutants in the water are effectively adsorbed by the activated carbon. In addition, there are some oxygen-containing functional groups on the amorphous part of the surface of the activated carbon, so that the organic pollutants in the water passing through the carbon bed are effectively adsorbed by the activated carbon. Activated carbon filter is a commonly used water treatment equipment. As a pretreatment of water treatment desalination system, it can effectively ensure the service life of the latter-stage equipment, improve the quality of the effluent, and prevent pollution, especially to prevent the latter-stage reverse osmosis membrane, ion exchange resin, etc. Free state residual chlorine poisoning pollution.

The main factors affecting the adsorption effect and service life of activated carbon filters are: the type and concentration of pollutants, the residence time of airflow in the filter material, and the temperature and humidity of the air.

In actual selection, the type of filter and the type of activated carbon should be determined according to conditions such as the type of pollutant, concentration and air volume to be treated.

The upstream and downstream of the activated carbon filter should have a good dust filter, and its efficiency specification should not be lower than F7. The upstream filter prevents dust from clogging the activated carbon material; the downstream filter blocks the dust from the activated carbon itself.

working principle

Activated carbon filter uses granular activated carbon to further remove residual chlorine, organic matter, and suspended impurities in the effluent of the mechanical filter, providing good conditions for subsequent reverse osmosis treatment.

The activated carbon filter mainly uses activated carbon organic flocs with high carbon content, large molecular weight and large specific surface area to physically adsorb impurities in the water to meet the water quality requirements. When the water flows through the pores of the activated carbon, various suspended particles, organic matter, etc. At the same time, the chlorine (hypochlorous acid) adsorbed on the surface of the activated carbon undergoes a chemical reaction on the surface of the activated carbon and is reduced to chloride ions, thereby effectively removing chlorine and ensuring that the residual chlorine in the effluent is less than 0.1 ppm, which meets the operating conditions of the RO membrane. With the passage of time, the retentate in the pores of the activated carbon and between the particles gradually increases, so that the pressure difference between the front and rear of the filter increases until it fails. Under normal circumstances, according to the pressure difference between the front and rear of the filter, reverse water flow is used to backwash the filter material, so that most of the retentate adsorbed in the pores of the activated carbon is stripped and taken away by the water flow, and the adsorption function is restored; when the activated carbon reaches the saturated adsorption capacity completely When it fails, the activated carbon should be regenerated or replaced to meet the engineering requirements.

Selection reference table

model

flow

T/h

Tank diameter

mm

Total height

mm

Exit and entry diameter

(mm)

Under pressure

MPa

YLD-CF-500

2

500

2350

DN32

0.6

YLD-CF-600

3

600

2380

DN32

0.6

YLD-CF-700

4

700

2400

DN40

0.6

YLD-CF-800

5

800

2400

DN40

0.6

YLD-CF-900

6

900

2500

DN50

0.6

YLD-CF-1000

8

1000

2600

DN50

0.6

YLD-CF-1200

11

1200

2700

DN65

0.6

YLD-CF-1400

15

1400

2800

DN65

0.6

YLD-CF-1500

18

1500

2850

DN65

0.6

YLD-CF-1600

20

1600

2900

DN80

0.6

YLD-CF-1800

25

1800

3000

DN80

0.6

YLD-CF-2000

30

2000

3100

DN100

0.6

YLD-CF-2200

38

2200

3180

DN100

0.6

YLD-CF-2400

45

2400

3330

DN100

0.6

YLD-CF-2500

50

2500

3380

DN100

0.6

YLD-CF-2600

55

2600

3430

DN125

0.6

YLD-CF-2800

60

2800

3530

DN125

0.6

YLD-CF-3000

70-80

3000

3630

DN125

0.6

YLD-CF-3200

80-100

3200

3730

DN150

0.6

The above data is for reference only, and the data of each product shipped shall prevail.

Consult now